CCR 30

Contact Closure Remote with Three LED Switches
Key Features
  • Three-button contact closure remote control panel for Extron switchers or control modules with contact closure ports
  • Switches can be individually configured for latching or momentary operation
  • LED ring lights provide visual feedback of switch status
  • Individually selectable internal or external tally input for control of LED lighting modes
  • LEDs can be powered by an external Extron Everlast™ power supply, part #70‑1175‑01
  • +12 VDC loop-out power port
The Extron CCR 30
Model Version Description Part #
CCR 30 Three LED switches, black 60-1446-02

The Extron CCR 30 provides simple, remote control of input selection on Extron switchers or control modules with contact closure control ports. The CCR 30 features three brushed aluminum pushbutton switches with blue LED ring lights for visual feedback. Switches can be individually configured for latching or momentary operation. The LEDs can be powered by any available 12 VDC power supply. To streamline installation, a +12 VDC power loop-out port allows sharing of external power with another Extron product. The LEDs can be controlled by the tally outputs on Extron switchers such as the MPS 601, or by an integrated tally driver circuit. The CCR 30 features a black anodized metal faceplate that complements Extron Cable Cubby® Series/2 cable access enclosures.

The CCR 30 provides remote control of a wide variety of functions. For example, switches configured for latching operation can power a display on or off, or raise or lower a motorized screen. Switches configured for momentary operation can be used for input selection, volume adjustment, or other functions.

The CCR 30 measures 1.75" (4.4 cm) high and 4.5" (10.16 cm) wide, providing a small footprint for integration wherever desired into tabletops and similar flat surfaces. Hidden clamps secure the faceplate to the furniture surface without tools or visible screws.

Custom, laser-etched faceplate labeling is available for easy identification of switch functions.

Features

OPTIONAL ACCESSORIES
  PS Series Desktop Power Supply 12 V & 15 V Replacement Power Supplies Featuring ZipClip®
RELATED PRODUCTS
  Cable Cubby 500 Cable Access Enclosure for AV Connectivity, Remote Control, and Power
  Cable Cubby 700 Cable Access Enclosure for AV Connectivity, Remote Control, and Power
  MPS 601 Media Presentation Switcher
  PC 101 AC Power Controller
  XTP T USW 103 Three Input XTP Switcher with Integrated XTP Transmitter

Specifications

CCR 30
Switch contact closure
   Quantity/type 3 normally open switches
   Connectors (2) 3.5 mm captive screw connector, 6 pole
   Contact output port (1) 3.5 mm captive screw connector, 6-pole
      Maximum current 
         Momentary 250 mA Sink from 6 VDC, maximum
         Latching 25 mA sink from 6 VDC, maximum
   Tally Out pins (1) 3.5 mm captive screw connector, 6-pole
      Maximum current 300mA sink from 6 VDC, maximum
    NOTE     Each switch can be used to select an input on a connected switcher.  See the CCR installation instructions for details.
    NOTE     Each switch can be configured in either single or toggle mode.  In single mode, a switch can be used to select an input on a connected switcher.  In toggle mode, a switch can be used to toggle display power on or off.  See the CCR 30 installation guide.
General
   Power input requirements 12 VDC, 0.04 A, (no load on Power Out connector)
12 VDC, 1.0 A (full load on Power Out connector),
supplied by an external power supply
   External power supply 100 VAC to 240 VAC, 50/60 Hz, external; to 12 VDC, 1 A, regulated
(External power supply is optional.)
   Power consumption 
      Device 0.3 watts, 12 VDC (no load on Power Out connector)
11.7 watts, 12 VDC (full load on Power Out connector)
      Device and power supply 0.7 watts, 100-240 VAC, 50-60 Hz (no load on Power Out connector)
15.0 watts, 100-240 VAC, 50-60 Hz (full load on Power Out connector)
   Temperature/humidity Storage: -13 to +131 °F (-25 to +55 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
   Cooling Convection, no vents
   Thermal dissipation 
      Device 1.0 BTU/hr (no load on Power Out connector)
40.0 BTU/hr (full load on Power Out connector)
      Device and power supply 2.1 BTU/hr (no load on Power Out connector)
50.9 BTU/hr (full load on Power Out connector)
   Mounting 
      Furniture mount Yes
         Min./max. table thickness 0.50” to 2.00”
      Rack mount No
   Enclosure type Metal
   Enclosure dimensions 
      Faceplate 1.75" H x 4.5" W x 0.2" D (4.4 cm H x 11.4 cm W x 0.5 cm D)
      Device 1.31" H x 3" W x 1" D (3.3 cm H x 7.6 cm W x 2.5 cm D)
   Product weight 0.3 lb (0.13 kg)
   Shipping weight 1 lb (<1 kg)
   Vibration ISTA 1A in carton (International Safe Transit Association)
   Regulatory compliance 
      EMI/EMC CE, FCC Class A
      Environmental Complies with the appropriate requirements of RoHS, WEEE
   Product warranty 3 years parts and labor
    NOTE     All nominal levels are at ±10%.
    NOTE     Specifications are subject to change without notice.
(8.1-063015-D3)
Shipping Dimensions and Weights
    Part # Height Width Depth Weight
    60-1446-02 2.63" (6.7 cm) 7.0" (17.8 cm) 5.38" (13.7 cm) 0.5 lbs (0.23 kg)

Diagram


Panel Drawing

Panel Drawing
© 2020 Extron. Specifications are subject to change without notice.